1. 实验室概况
流体包裹体是封存在矿物和岩石中的古流体,是岩浆活动和成矿作用过程留下的“遗迹化石”,记录了原生岩浆及演化、成矿元素迁移及富集机制的信息。目前,包裹体已经成为探讨矿床成因和揭示岩浆起源及演化的重要手段。矿物学与成矿学重点实验室流体包裹体实验室配有法国HORIBA Scientific产XPLORA PLUS型可见显微共焦拉曼光谱仪、加拿大BII CLF-2阴极发光仪、英国产Linkam ThMS 600型冷热台两台、Linkam TS 1400XY型高温热台及加装红外摄像头的Nikon LV100N POL偏光显微镜等设备,建成了能够开展透明矿物包裹体(熔融和流体)和少量不透明矿物(辉锑矿和黑钨矿)流体包裹体显微测温及成分分析的包裹体实验室。
2. 仪器介绍
1)法国HORIBA XPLORA PLUS显微共焦拉曼光谱仪 2)加拿大 BII CLF-2阴极发光仪 3)英国Linkam ThMS 600型冷热台 4)英国Linkam TS 1400XY型高温热台 5)加装红外摄像头的Nikon LV100N POL偏光显微镜 6)流体包裹体实验室显微测温室
3. 实验室成员
![]() | 平台实验室主任:李宁波,副研究员,从事岩浆岩岩石学和矿床地球化学研究,负责实验室主要研究方向和工作管理。 联系电话:020-85290243(座机)/ 13250244006 Email:liningbo@gig.ac.cn 办公地点:标本楼538房间 |
![]() | 实验室技术主管:屈潘,博士生,从事成因矿物学与矿床地球化学研究,负责仪器日常运行管理和维护维修。 联系电话:18565477760 Email: qupan@gig.ac.cn 办公地点:标本楼404房间 |
![]() | 实验室助理:赵晓晨,博士生,从事矿床地球化学研究,负责阴极发光仪日常运行管理和维护维修。 联系电话:18829890907 Email: zhaoxiaochen@gig.ac.cn 办公地点:标本楼404房间 |
![]() | 实验室助理:张东,博士生,从事矿物学和矿床学研究,负责激光拉曼日常运行管理和方法开发。 联系电话:17749134388 Email: zhangdong@gig.ac.cn 办公地点:标本楼304房间 |
![]() | 实验室助理:杨玉元,博士生,从事矿物学和矿床学研究,负责流体/熔体包裹体显微测温日常运行管理和维护维修。 联系电话:18701586802 Email:yangyuyuan@gig.ac.cn 办公地点:标本楼304房间 |
![]() | 实验室助理:付瑞鑫,博士生,从事矿物学和矿床学研究,协助包裹体显微测温日常运行管理和维护维修。 联系电话:18194893432 Email:furuixin@gig.ac.cn 办公地点:标本楼302房间 |
4. 工作内容
1) 矿物中流体包裹体气相、液相、固相成分的分析和岩石内部微细矿物的鉴定
2) 阴极发光显示矿物(磷灰石、方解石、白云石、石英、长石等)的内部结构(环带构造、裂隙等),用于矿物的种类、成因的鉴别及先后形成世代的确定等。
3) 脉石矿物(石英、萤石、方解石、石榴石等)中流体包裹体的均一温度、冷冻温度(含盐度)和岩浆岩中熔融包裹体均一温度的精确测定。
5. 用户须知
1)实验条件与方法说明
1. 激光拉曼。节选自Qu et al. (2019) 供参考:Laser Raman spectra of zircon crystals were collected using the Horiba Xplora laser Raman microscope at KLMM, GIGCAS. An Ar+ ion laser operating at 44 mW was used to produce an excitation wavelength of 532 nm. The scanning range of the spectra was set to 100–4000 cm−1 and the accumulation time for each scan was set to 8 s. The spectral resolution and beam diameter were 2 cm−1 and 1 μm, respectively. The Raman shift of a monocrystalline silicon sample (520.7 cm−1) was used for calibration before the analysis.
2. 阴极发光。节选自Qu et al. (2021) 供参考: Cathodoluminescence petrography (CL) was performed both on a Leica DM2700P binocular petrographic microscope with a CLF-2 CL system, at the Key Laboratory of Mineralogy and Metallogeny, GIGCAS. The voltage for the systems was held between 13 and 15 kV, current ranging from 240 to 260 μA, and chamber vacuum between 50 and 60 millitorr.
3. 包裹体测温。节选自Jiang et al. (2017) 供参考: Microthermometry study was carried out using a Linkam TS 600 Heating-Freezing System at the Key Laboratory of Mineralogy and Metallogeny, Chinese Academy of Sciences (hereafter referred to as KLMMCAS). Thermocouples were calibrated at −196 to 600 °C using synthetic FIs. The precision of temperature measurement is ±0.1 °C between −100 and 25 °C, ±1 °C between 25 and 400 °C, and±2 °C above 400 °C. The heating rate was generally 0.2 to 5 °C/min during the analysis, but reduced to 0.1 °C/min near the freezing point, and 0.2 to 0.5 °C/min near the homogenization temperature to record the phase transformation process accurately.
2)关于成果致谢 (Acknowledgement)
凡出自本实验室的实验数据发表的文章,请按照规范在方法或致谢中提及相应的设备和技术人员的支撑工作(仅便于仪器的共享成果与奖励机时统计)。举例:We thank XXX at the Fluid inclusion Laboratory, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences (GIGCAS), for their efforts to maintain operation in XXX experiments.
中国科学院矿物学与成矿学重点实验室流体包裹体实验室秉承开放和合作的宗旨,欢迎国内外学者来实验室开展分析与合作研究!
6. 收费须知
测试项目 | 所内收费 | 所外收费 | 备注:所有实验过程均由送样人完成 |
激光拉曼光谱 | 400/小时 | 500/小时 | 薄片或靶子均可 |
冷阴极发光 | 400/小时 | 500/小时 | 薄片或靶子均可 |
流体包裹体显微测温 | 1000/天 | 1500/天 | 薄片 |
熔体包裹体显微测温 | 1500/天 | 2000/天 | 薄片 |
以上收费标准本实验室保留决定权、解释权,如有变化恕不另行通知。
7. 欢迎来访
实验室详细地址:广州市天河区科华街511号科学院地化所标本楼103房间
邮政编码:510640
实验室联系电话:020-85290243